Enquiry now

York Scheibel's Extraction Column manufacturer in india

MODAL NO: MTMT-102

QTY


The York Scheibel's Column falls in the class of gravity-operated extractors with mechanical agitation. The presence of alternatively agitating and calming sections in a York Scheibel's column yield higher extraction efficiency than the conventional packed column. In the setup acontinuous counter current contact between the solvent and solute phases is made which results into extract and raffinate streams. Rotameters are used to measure the flow of solvent and solute respectively.

The York Scheibel's Column falls in the class of gravity-operated extractors with mechanical agitation. The presence of alternatively agitating and calming sections in a York Scheibel's column yield higher extraction efficiency than the conventional packed column. In the setup acontinuous counter current contact between the solvent and solute phases is made which results into extract and raffinate streams. Rotameters are used to measure the flow of solvent and solute respectively. The continuous and dispersed phase streams are metered and derivedfrom separate containers. Each stage consists of a woven wire mesh section and a mixing section. The propeller speed can be controlled to the desired value by a controller. Total set-up is housed in a well-designed rigid structure. The structure also supports tanks, piping, Rotameter, panel and other units.

•Arrangement is done for changing height of interface zone.

•Control panel comprising of: Standard make on/off switch, Mains Indicator etc.

•An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus.

•The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.

Experimentation/Learning Objectives

•To determine overall mass transfer co-efficient based on continuous & dispersed phase.

•To determine individual `Height of Transfer Unit' based on continuous & dispersed phase.

•To determine overall `Height of Transfer Unit' based on continuous & dispersed phase.


Extraction ColumnMaterial Borosilicate Glass Dia. 45 mm, Height 750 mm (approx).
PackingWoven mesh of Stainless Steel
AgitatorStainless Steel/Teflon impellers with Stainless Steel shaft coupled to a Variable Speed DC Motor.
RPM Measurement Digital RPM Indicator, non contact type with Proximity sensor.
Feed Tank (2 Nos). .Material Stainless Steel, Capacity 20 Ltrs
Extract & Raffinate TanksMaterial Stainless Steel (1 each), Capacity 10 Ltrs.
Feed CirculationBy Compressed Air
Pressure Regulator0-2 kg/cm².
Pressure GaugeBourdon type, 0-2 kg/cm2.
Flow MeasurementRotameters (One each for solvent & solute)