Enquiry now

Parallel Flow/Counter Flow Heat Exchanger manufacturer in india

MODAL NO: MTHT-121

QTY


The present set-up is designed to study the heat transfer in parallel and counter flow in concentric tube heat exchanger. Hot water flows through inner tube, cold water flows through the outer tubes and can be operated in parallel or counter mode with respect to hot water. For hot water, a recirculating type water bath having PID temperature controller and a magnetic pump is provided. Cold water at constant head condition is to be provided from laboratory overhead tank. The flow rates are measured using Rotameters. The temperature of hot and cold fluids at inlet and outlet of heat exchanger can be measured by Digital Temperature Indicator.

The present set-up is designed to study the heat transfer in parallel and counter flow in concentric tube heat exchanger. Hot water flows through inner tube, coldwater flows through the outer tubes and can be operated in parallel or counter mode with respect to hot water. For hot water, a recirculating type water bath having PID temperature controller and a magnetic pump is provided. Cold water at constant head condition is to be provided from laboratory overhead tank. The flow rates are measured using Rotameters. The temperature of hot and cold fluids at inlet and outlet of heat exchanger can be measured by Digital Temperature Indicator.

  • An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus.
  • The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.

Experimentation/Learning Objectives

•To calculate the Rate of Heat Transfer

•To calculate the LMTD.

•To calculate the Overall heat transfer co-efficient.

•To compare the performance of Parallel and Counter flow heat exchanger.

Utilities Required

•Water supply: 5 lit/min (approx.) and drain.

•Electricity Supply: 1 Phase, 220 V AC, 50 Hz, 32 amp MCB with earth connection (Earth voltage should be less than 5 volts)

•Floor area: 2 m x 0.6m  

SystemWater to Water, concentric tube type
Heat ExchangerLength 1.6m (approx.). insulated with ceramic wool and cladded by aluminum foil.
Outer Tube Material Stainless steel. ID 27.5 mm, OD 33.8 mm (approx.)
Inner TubeMaterial Stainless Steel, ID 9.5 mm, OD 12.7mm (approx.)
Water Flow Measurement Rotameters (2Nos.) one each for cold & hot fluid.
Hot Water TankMade of Stainless steel (Insulated with ceramic wool)
Hot Water CirculationMagnetic Pump
Heaters Nichrome wire heater (2Nos)
Control panel comprising of :

Digital Temp. Controller PID Controller, 0-199.9°C (For Hot Water Tank) Digital Temp.

Indicator : 0-199.9°C, with multi-channel switch

Temperature Sensors : RTD PT-100 type-5Nos.

Non Contact type.With Standard make On/Off switch, Mains Indicator etc.

Related Products