Enquiry now

DIRECTIONAL AND NON DIRECTIONAL OVER CURRENT PROTECTION RELAY TRAINER manufacturer in india

MODAL NO: MT-E864

QTY


SCOPE OF LEARNING: 

To perform experiment on IDMT over current protection.

To perform experiment on under/over voltage protection.

To perform experiment on under/over frequency protection.

To perform experiment on earth fault protection.

SCOPE OF LEARNING: 

To perform experiment on IDMT over current protection.

To perform experiment on under/over voltage protection.

To perform experiment on under/over frequency protection.

To perform experiment on earth fault protection.

To perform experiment on negative sequence over current protection.

To perform experiment on zero sequence over voltage protection.

To perform experiment on negative sequence over voltage protection.

To perform experiment on Phase Balance and Phase Imbalance

Power Supplies:

AC Power Supply 0-415V, 6A

Operated on Mains power 415V, 50Hz +10%

THREE PHASE POWER SUPPLY MODULE (415V,50Hz)

MCB

Emergency Stop

R-Y-B Indicator

 MULTIFUCTION METER MODULE

Digital Multi Function Meter. Measures V, I, PF (0.2 lag – unity 0.2 lead), Hz.

DIGITAL METER MODULE (FOR AC)

Digital Voltmeter AC

Digital Ammeter AC 

CURRENT TRANSFORMER MODULE

Current Transformer (3Units) 

POTENTIAL TRANSFORMER MODULE

Potential Transformer (3Units)

TRIPPING INDICATION MODULE

Lamp Holder 230V (2Units)

DISTANCE PROTECTION RELAY MODULE

Protections: Over current, Under/Over voltage, Earth fault, Directional Current, Phase Balance, Phase Imbalance

Auto reclose function of relay

9 pin D (M) connector to interface with RTU/SCADA for automation.

Modbus RTU RS 485 for RTU/SCADA interface.

3PHASE CURRENT SOURCE MODULE

CIRCUIT FOR DIRECTIONAL RELAY

SALIENT FEATURES:

Front panel built with high class insulated Printed Circuit Breaker well printed circuits and symbols.

Instruction manual.

Patch Cords 4mm (Heavy Duty) 1Meter Length. 

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet. 

Short Circuit protection with the MCB.

Size of the trainer set 42”x24” 

OPTIONAL ACCESSORIES:

No

PACKING LIST

MT-E864 DIRECTIONAL AND NON DIRECTIONAL OVER CURRENT PROTECTION RELAY TRAINER

PATCH CORDS

3PHASE RESISTIVE LOAD UNIT

FILAMENT LAMP (2Units)

3PHASE AUTO TRANSFORMER UNIT

Cables:

RS232 PORT FOR PC COMMUNICATION, RELAY SETTING WITH SOFTWARE ON CD, RS232 TO USB CONVERTER FOR USB INTERFACE


DIRECTIONAL AND NON DIRECTIONAL OVER CURRENT PROTECTION RELAY TRAINER manufacturer in india

Related Products