SCOPE OF LEARNING:
• Measurement and Analysis of Different parameters of Solar PV Module : open circuit and short circuit, parameter measurement with series and parallel PV modules , I-V characteristic and Power curve of PV module and PV array , efficiency and fill factor
• Study of Wind Power and Wind Energy.
• Load Estimation and calculation
• Study of Charge controller
• Study of different parameter of inverter efficiency , PWM switching , charging of batteries , over load and over battery protection
SCOPE OF LEARNING:
• Measurement and Analysis of Different parameters of Solar PV Module : open circuit and short circuit, parameter measurement with series and parallel PV modules , I-V characteristic and Power curve of PV module and PV array , efficiency and fill factor
• Study of Wind Power and Wind Energy.
• Load Estimation and calculation
• Study of Charge controller
• Study of different parameter of inverter efficiency , PWM switching , charging of batteries , over load and over battery protection
SALIENT FEATURES:
• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.
• The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet.
• Instruction manual.
• Patch Cords 4mm (Heavy Duty)
• High Voltage Test Points are Provided With 4mm Safety Sockets
• Short Circuit protection with the MCB.
• Size of the trainer set 48”x24”
SCOPE OF SUPPLY:
• Renewable Power Generation And Training System
• Battery Bank 4Nos.
• Wind Turbine
• Fan Blower
• Solar Cell 4Nos.
• Patch Cords
• Filament Lamp 6Nos.
• Manual
TECHNICAL SPECIFICATIONS:
Power Supplies:
• Operated on Mains power 230V, 50Hz +10%
Digital/Analog Meters:
DC Voltmeter : 0-300V
DC Ammeter : 0-40A
AC Voltmeter : 0-300V
AC Ammeter : 0-40A
Multi Function Meter
• Voltage-10-230V
• Current-100mA-5A
• Watt-10-1200W
• Energy meter
• Display Resolution- 0.001kWh
• Frequency-50Hz
CONTROL PANEL WITH INVERTER:
• Capacity: 1000VA
• Input Voltage: 190~260V AC
• Output Voltage on Mains mode: same as input
• Output Voltage on UPS mode: 210~245V
• Output Frequency on UPS mode: 50Hz ±0.1Hz
• Output waveform on Mains mode: same as input
• Output waveform on UPS mode: Modified Sine wave
• Battery Charging Current: 12A
• Efficiency at full load : >80% UPS Overload/UPS Short circuit: Yes
• Technology: Microcontroller based
• MCB: C Type 16A-1nos
BATTERY:
• Solar Battery Capacity : 12V/100Ah
• Type : C10
• Qty: 4 Nos.
Power And Charge Controller Unit (Solar):
• Solar PV Module : 24–50V
• Current : 40A
• Battery voltage : 24V
• Technology : PWM based
• Charging Stage : Bulk, Absorptions and Float
Power And Charge Controller Unit (Wind):
• Solar PV Module : 24–50V
• Current : 40A
• Battery voltage : 12V
• Technology : PWM based
• Charging Stage : Bulk, Absorptions and Float
• Solar Panels With Stand 1000W
• Pm : 250Wp
• Voc : 43V
• Isc : 7.75A
• Vmp: 35V
• Imp : 7.14A
• Qty : 4Nos.
• Wind Turbine 300W
• Wattage: 300W
• Output: 24V DC
• Blades: 3Nos.