OVERVIEW:
• Miniature form of Generation, Transmission, Protection and Distribution System
WHAT WE ARE OFFERING:
1. MT-E476: POWER GENEATION AND PARALLEL OPERATIONS OF TWO ALTERNATORS (SYNCHRONIZATION OF TWO ALTERNATORS)
• DC Shunt Motor Coupled With Synchronous Generator 2Nos.
• Power Generation and Parallel Operation of Synchronous Generator Control Panel 1Nos.
2. MT-E281D: THREE PHASE TRANSMISSION LINE TRAINER
• 3Phase Auto Transformer Unit
• 3Phase Resistive Load
• 3Phase Inductive Load
• 3Phase Capacitive Load
3. MT-E291A: 3 PHASE POWER DISTRIBUTION TRANSFORMER TRAINER
• 3Phase Transformer Unit 1.5KVA
• 3Phase Auto Transformer Unit
4. MT-E704B: PROTECTIVE RELAYING TRAINING SYSTEM (PROTECTION)
MT-E476 PARALLEL OPERATIONS OF TWO ALTERNATORS (SYNCHRONIZATION OF TWO ALTERNATORS)
SCOPE OF LEARNING:
• Study of Parallel Operations of Two Ac Alternator (Synchronizing the 2 Alternator)
• Study of Operation of DC Shunt Motor
• Study of Operation of 3Phase Synchronous Generation.
• Study of Dark Lamp Method using Parallel Operations of Two Ac Alternator
• Study of Bright Method using Parallel Operations of Two Ac Alternator
• TECHNICAL SPECIFICATIONS:
Power Supplies:
• DC Power Supply 0-230V AT 2A (Field Control) 2Nos.
• DC Power Supply +230V AT 2A (Field Control) 2Nos.
• Operated on Mains power 230V, 50Hz +10%
Digital/Analog Meters:
• Voltmeter DC 2Nos.
• Frequency Monitoring Relay 2Nos.
• Frequency Meter 2Nos.
• Ammeter DC 4Nos.
• Voltmeter AC 2Nos.
• Ammeter AC 2Nos.
• Synchroscope 1Nos.
• RPM Meter 2Nos.
• Multifunction Meter 2Nos.
• Components are mounted on the panels are:
• Three Phase Lamp Load Switched Control
• Synchronizing Lines For Parallel Operations.
• Output Through 4Pole MCB (For Alternators)
• 3 Point Starter 2Nos.
• Color Indication For Output
• Variac (For Field Control Power Supply) 2Nos.
SALIENT FEATURES:
• Voltage regulation within limit as per ISS.
• Special guard also provided on the coupling to avoid any mis-happening during operation.
• D.C. Motor Shunt 2HP coupled with A.C. Alternator
1KVA (Separately or self Excited.
• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.
• Instruction manual.
• Patch Cords 4mm (Heavy Duty) 1Meter Length.
• High Voltage Test Points are Provided With 4mm Safety Sockets
• The trainer is housed in Metal cabinet.
• Short Circuit protection with the MCB.
• Size of the trainer set 65”x24”
OPTIONAL ACCESSORIES:
• No
SCOPE OF SUPPLY:
• DC Motor 2HP, 230V and AC Synchronous Alternator (1KW). (2Nos.)
• Synchronizing of Two Alternators Control Panel (1Nos.)
MOTOR SPECIFICATIONS:
• DC Shunt Motor 2HP
• Operating Voltage:230V
• Type: DC
• RPM: 1440 RPM.
• Wattage: 1.5KW
• Terminations: 4 BTI 15 Terminals
• Shaft: Single
• Frame:132
• B3
• SPDP
• 1P23
• 1C01
• Solid Yoke Extension
• Fitted on Metal Base.
GENERATOR SPECIFICATIONS:
• AC Alternator 1KW
• Operating Voltage:415V
• Type: AC
• RPM: 1440 RPM.
• Wattage: 1KW
• Terminations: 5 BTI 15 Terminals
• Shaft: Single
• Frame:132
• B3
• SPDP
• 1P23
• 1C01
• Solid Yoke Extension
• Fitted on Metal Base.
MT-E281D THREE PHASE TRANSMISSION LINE TRAINER
SCOPE OF LEARNING:
• Study of Three Phase Transmission Lines
• TECHNICAL SPECIFICATIONS:
Power Supplies:
• AC Power Supply 0-415V AT 4A (Optional)
• Operated on Mains power 415V, 50Hz +10%
Digital/Analog Meters:
• Voltmeter 2 Nos.
• Ammeter 2Nos.
• 4A Variac (3 Phase)
• Transmission Lines 400Km (Through Resistor-Capacitor and Inductors)
SALIENT FEATURES:
• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.
• Instruction manual.
• Patch Cords 4mm (Heavy Duty) 1Meter Length.
• High Voltage Test Points are Provided With 4mm Safety Sockets
• The trainer is housed in Metal cabinet.
• Short Circuit protection with the MCB.
• Size of the trainer set 30”x24”
ACCESSORIES:
• Resistive Load
• Capacitive Load
• Inductive Load
MT-E291A 3 PHASE POWER DISTRIBUTION TRANSFORMER TRAINER
SCOPE OF LEARNING:
• Study of 3 Phase Transformer Distribution System
• TECHNICAL SPECIFICATIONS:
Power Supplies:
• AC Power Supply 0-415V AT 4A (Optional)
• Operated on Mains power 415V, 50Hz +10%
Digital Meters:
• Voltmeter (For Primary and Secondary)
• Ammeter (For Primary and Secondary)
Components are mounted on the panels are:
• 3 Phase Lamp Load (Start Connected) Switched Control
• 3 Phase Lamp Load Ring System
• 3 Phase Transformer Unit (440V/220V) Copper Winding
• Emergency Stop
SALIENT FEATURES:
• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.
• Instruction manual.
• Patch Cords 4mm (Heavy Duty) 1Meter Length.
• High Voltage Test Points are Provided With 4mm Safety Sockets
• The trainer is housed in Rack Type Channel Extruded Panel
• Panel is modular based easy to place and remove the Module.
• Short Circuit protection with the MCB.
• Size of the trainer set 42”x24”
OPTIONAL ACCESSORIES:
• Resistive Load.
MT-E704B PROTECTIVE RELAYING TRAINING SYSTEM (PROTECTION)
SCOPE OF LEARNING:
• Study about different protection techniques
• Current Transformer and Potential Transformer
• Voltage Monitoring Relay (Single and Three Phase)
• Over Current Relay (Single andThree Phase)
• Reverse Power Relay
• Phase Sequence Relay
• Three Phase Power Factor Relay
• Synchro Check Relay
• Frequency Monitoring Relay (Three Phase)
TECHNICAL SPECIFICATIONS:
• MCB (Power Switch) : Three Phase 10A
• Interconnections : 4mm Safety Socket
• Current Transformer and Potential Transformer
• Voltage Monitoring Relay (Single and Three Phase)
• Over Current Relay (Single andThree Phase)
• Reverse Power Relay
• Phase Sequence Relay
• Three Phase Power Factor Relay
• Synchro Check Relay
• Frequency Monitoring Relay (Three Phase)
• Wattmeter/ Var Meter
• Power Factor Meter
Power supplies:
• Single Phase AC Power Supply : 220V, 50/60Hz
• Three Phase AC Power Supply :230V Phase voltage, 415 Line voltage ± 10% 50 Hz
• Operated on Mains power 415V, 50Hz +10%
SALIENT FEATURES:
• Light Indicator for Mains.
• Front panel built with high class insulated Printed Bakelite/Aluminum Board sheet with well printed circuits and symbols.
• 4 Pole MCB for Short Circuit protection
• Instruction manual.
• Emergency Stop also Provided
• Connections are brought out through 4mm Colored Safety Sockets.
• Patch Cords 4mm
• The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet.
• Size of the trainer set 54’’x24”
OPTIONAL ACCESSORIES:
• No
SCOPE OF SUPPLY (PACKING LIST):
• Patch Cords 4mm
• PROTECTIVE RELAYING TRAINING SYSTEM (PROTECTION)
ELECTRICAL POWER SYSTEM TRAINER ELECTRICAL POWER SIMULATOR TRANSMISSION DISTRIBUTION AND CONTROL manufacturer in india