ELECTRICAL POWER SYSTEM SIMULATOR TRAINER ELECTRICAL POWER SIMULATOR TRANSMISSION, DISTRIBUTION AND CONTROL manufacturer in india

MODAL NO: MT-E899A

QTY


ELECTRICAL POWER SYSTEM SIMULATOR TRAINER ELECTRICAL POWER SIMULATOR TRANSMISSION, DISTRIBUTION AND CONTROL manufacturer in india

OVERVIEW:

Miniature form of Generation, Transmission, Protection and Distribution System Simulator

WHAT WE ARE OFFERING:

1. MT-E476: POWER GENEATION AND PARALLEL OPERATIONS OF TWO ALTERNATORS (SYNCHRONIZATION OF TWO ALTERNATORS)

DC Shunt Motor Coupled With Synchronous Generator 2Nos.

Power Generation and Parallel Operation of Synchronous Generator Control Panel 1Nos.

2. MT-E344 Generator Protection Trainer

3. MT-E740 Transmission and Distribution Trainer

3Phase Transmission Line Module Unit

3Phase Auto Transformer Unit

3Phase Resistive Load

3Phase Inductive Load

3Phase Capacitive Load

4. MT-E704B: PROTECTIVE RELAYING TRAINING SYSTEM (PROTECTION)

5. Transformer:

5 KVA, 415V/3.3KV, 50 Hz, Y-d type –2 nos.

5 KVA, 3.3KV/415 V, 50 HZ, D-Y type –1no.

6 Loads:

3-Phase induction motor (415 V, 5 hp) with mechanical loading- 2nos.

1-Phase induction motor (1 hp, 230 V, permanent capacitor type) with mechanical loading-3 Nos.

MT-E476 PARALLEL OPERATIONS OF TWO ALTERNATORS (SYNCHRONIZATION OF TWO ALTERNATORS)

SCOPE OF LEARNING: 

Study of Parallel  Operations of Two Ac Alternator (Synchronizing the 2 Alternator)

Study of Operation of DC Shunt Motor 

Study of Operation of 3Phase Synchronous Generation.

Study of Dark Lamp Method using Parallel  Operations of Two Ac Alternator

Study of Bright Method using Parallel  Operations of Two Ac Alternator

TECHNICAL SPECIFICATIONS: 

Power Supplies:

DC Power Supply 0-230V AT 2A (Field Control) 2Nos.

DC Power Supply +230V AT 2A (Field Control) 2Nos.

Operated on Mains power 230V, 50Hz +10%

Digital/Analog Meters:

Voltmeter DC 2Nos.

Ammeter DC 4Nos.

Voltmeter AC 2Nos.

Ammeter AC 2Nos.

Synchroscope 1Nos.

RPM Meter 2Nos.

Multifunction Meter 2Nos.

Components are mounted on the panels are:

Three Phase Lamp Load Switched Control

Synchronizing Lines For Parallel Operations.

Output Through 4Pole MCB (For Alternators)

Automatic Synchronization Relay

3 Point Starter 2Nos.

Color Indication For Output

Variac (For Field Control Power Supply) 2Nos.

SALIENT FEATURES:

Voltage regulation within limit as per ISS.

Special guard also provided on the coupling to avoid any mis-happening during operation.  

D.C. Motor Shunt 2HP coupled with A.C. Alternator

1KVA (Separately or self Excited.        

Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.

Instruction manual.

Patch Cords 4mm (Heavy Duty) 1Meter Length.

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Metal cabinet. 

Short Circuit protection with the MCB. 

Size of the trainer set 65”x24” 

OPTIONAL ACCESSORIES: 

No

SCOPE OF SUPPLY:

DC Motor 230V and AC Synchronous Alternator  (2Nos.)

Synchronizing of Two Alternators Control Panel (1Nos.)

MT-E344 MOTOR GENERATOR TRAINER WITH PROTECTION RELAY UNIT

SCOPE OF LEARNING: 

Study of generator protection for differential, over current, over/under voltage, over/under frequency, reverse power and earth faults using generator protection relay

TECHNICAL SPECIFICATIONS AL-E314: 

MAIN MODULE 

Digital Voltmeter AC

Digital Ammeter AC

Filament Lamp with Holder 6Nos.

MCB 4Pole

Indicator R-Y-B-G

SALIENT FEATURES:

Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.

The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet. 

Instruction manual.

3 Phase and 1 Phase Power Indication With 25mm Colored Indicators

Patch Cords 4mm (Heavy Duty)

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Metal cabinet. 

Protection with Emergency Stop.

Short Circuit protection with the MCB. 

Size of the trainer set 30”x24” 

TECHNICAL SPECIFICATIONS AL-E434: 

Power Supplies:

AC Power Supply 0-230V,2A

Operated on Mains power 230V, 50Hz +10%

THREE PHASE POWER SUPPLY MODULE (415V,50Hz)

MCB

Emergency Stop

R-Y-B Indicator

 SINGLE PHASE SUPPLY AND TRIPPING INDICATION MODULE

Lamp Holder 230V (2Units)

MCB

Red Indicator 

MULTIFUCTION METER MODULE 

Digital Multi Function Meter 

CURRENT TRANSFORMER MODULE

Current Transformer (3Units) 

POTENTIAL TRANSFORMER MODULE

Potential Transformer (3Units)

AVR MODULE

Automatic Voltage Regulator

GENERATOR PROTECTION RELAY MODULE

Numerical type Generator Protection Relay

RS232 PORT FOR PC COMMUNICATION, RELAY SETTING WITH SOFTWARE ON CD, RS232 TO USB CONVERTER FOR USB INTERFACE

Buzzer/Indicator

Connection Strip (2Units)

3PHASE CURRENT SOURCE MODULE

Circuit for Generator Protection Relay

Digital Ammeter AC

Digital Timer

SALIENT FEATURES:

Front panel built with high class insulated Printed Circuit Breaker well printed circuits and symbols.

Instruction manual.

Patch Cords 4mm (Heavy Duty) 1Meter Length. 

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet. 

Short Circuit protection with the MCB.

Size of the trainer set 42”x24” 

OPTIONAL ACCESSORIES:

No

MT-E740 POWER TRANSMISSION AND DISTRIBUTION PROTECTION TRAINING SYSTEM 

SCOPE OF LEARNING: 

Study of No load test and Ferranti effects on transmission line.

Load test and calculation of efficiency, regulation and power flow in pi model of TL.

Load test and calculation of efficiency, regulation and power flow in short model of TL

Study of symmetrical and asymmetrical faults on transmission line.

Study of distance protection using distance relay.

Studies of Auto reclose function of distance relay.

Study of Distribution transformer protection for differential & over current faults.

Power Supplies:

AC Power Supply 0-415V, 4A

Operated on Mains power 415V, 50Hz +10%

SINGLE PHASE POWER SUPPLY MODULE

MCB

Red Indicator

Digital Timer

Reset Switch 

THREE PHASE POWER SUPPLY MODULE (415V,50Hz)

MCB

Emergency Stop

R-Y-B Indicator

 MULTIFUCTION METER MODULE 2NOS.

Digital Multi Function Meter. Measures V, I, PF (0.2 lag – unity 0.2 lead), Hz.

FORWARD/ REVERSE SWITCH MODULE 

? FWD/REV, 3 pole 3 way switch with center OFF, 6A/440V.

CAPACITOR SELECTION MODULE 

? Consisting of VAR compensating capacitors of 2, 4, 6, 8, 10 & 15µF each of 3nos with 3 pole 7 way switch for selection.

DIGITAL METER MODULE (FOR AC)

Digital Voltmeter AC

Digital Ammeter AC 

CURRENT TRANSFORMER MODULE

Current Transformer (3Units) 

SOURCE LINE IN MODULE 

Circuit Connection In

TRIPPING INDICATION MODULE

Lamp Holder 230V (2Units)

POTENTIAL TRANSFORMER MODULE

Potential Transformer (3Units)

TRANSMISSION LINE OUT MODULE 

Connection Out For Transmission Line 

DIFFERENTIAL RELAY (TRANSFORMER PROTECTION) MODULE  1 NO.

Protections: Differential, over current, Under/Over voltage, Under/Over frequency, Reverse power, Earth fault.

9 pin D (M) connector to interface with RTU/SCADA for automation.

Modbus RTU RS 485 for RTU/SCADA interface.

DISTANCE PROTECTION RELAY MODULE

Protections: Distance, Over current, Under/Over voltage, Earth fault.

Auto reclose function of relay

9 pin D (M) connector to interface with RTU/SCADA for automation.

Modbus RTU RS 485 for RTU/SCADA interface.

3PHASE CURRENT SOURCE MODULE

CIRCUIT FOR DISTANCE RELAY

9PIN  JOHNSON CONNECTOR

9PIN  JOHNSON CONNECTOR 

1. TRANSMISSION LINE PANEL TABLE TOP PANEL CONSISTING OF:

? Simulate model for transmission line constructed using R(10ohm/600W), L(0.15H/5A) and C (2.2uF/630V) 6 No. each component.

? Can Simulate model for medium/long (125 km/250 km) length transmission line for ? model.

? Can Simulate model for medium/long (125 km/250 km) length transmission line for T model.

? Fan cooled table top setup for long life.

2. RLC LOAD CONSISTING OF:

? 3nos of 1KW resistors with switch selectable 1(off) + 6 nos. of taps at 100, 112, 150, 175, 200 & 225 ohm & SIL tap of 262 ohm.

? 3 nos. of inductor 1.5H/1A with switch selectable 1(off) + 6 nos. of taps at 0.3, 0.6, 0.75, 0.9, 1.2 & 1.5H.

? Capacitors 440VAC rating (3nos, one per phase) with switch selectable 7nos of value of 2, 5, 10, 15, 20, 30 & 50µF.

? Fan cooled table top setup.

3. 3 PHASE DIMMER PANEL TABLE TOP PANEL CONSISTING OF:

? 3 Phase dimmer I/P : 415VAC, 50Hz, O/P : 0 - 470 V AC, 6A, 3 phase.

4. DISTRIBUTION TRANSFORMER 1 NO.

3 Phase power transformer with connection group YY11,

Input 415VAC, Output 415VAC, 3KVA,

Secondary winding with tapping at +2.5% and +5%.

TRANSMISSION LINE PANEL: 

Table Top Panel consisting of :

Simulated model for short transmission line using R(10 ohm/600W), L(0.15H/5A) & C (2.2uF/630V) 6 No. each component.

Simulated model for medium length 125kms & long lenth 250kms transmission line.

Forced Air cooled using 2 fans.

SALIENT FEATURES:

Front panel built with high class insulated Printed Circuit Breaker well printed circuits and symbols.

Instruction manual.

Patch Cords 4mm (Heavy Duty) 1Meter Length. 

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet. 

Short Circuit protection with the MCB.

Size of the trainer set 54”x24” 

OPTIONAL ACCESSORIES:

No

MT-E704B PROTECTIVE RELAYING TRAINING SYSTEM (PROTECTION)

SCOPE OF LEARNING: 

Study about different protection techniques

Current Transformer and Potential Transformer 

Voltage Monitoring Relay (Single and Three Phase)

Over Current Relay (Single andThree Phase) 

Reverse Power Relay

Phase Sequence Relay

Three Phase Power Factor Relay

Synchro Check Relay

Frequency Monitoring Relay (Three Phase)

 TECHNICAL SPECIFICATIONS: 

MCB (Power Switch) : Three Phase 10A 

Interconnections : 4mm Safety Socket

Current Transformer and Potential Transformer

Voltage Monitoring Relay (Single and Three Phase)

Over Current Relay (Single andThree Phase)

Reverse Power Relay

Phase Sequence Relay

Three Phase Power Factor Relay

Synchro Check Relay

Frequency Monitoring Relay (Three Phase)

Wattmeter/ Var Meter

Power Factor Meter

Power supplies:

Single Phase AC Power Supply : 220V, 50/60Hz 

Three Phase AC Power Supply :230V Phase voltage, 415 Line voltage ± 10% 50 Hz

Operated on Mains power 415V, 50Hz +10%

SALIENT FEATURES:

Light Indicator for Mains.

Front panel built with high class insulated Printed Bakelite/Aluminum Board sheet with well printed circuits and symbols.

4 Pole MCB for Short Circuit protection 

Instruction manual.

Emergency Stop also Provided

Connections are brought out through 4mm Colored Safety Sockets.

Patch Cords 4mm

The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet. 

Size of the trainer set 54’’x24” 