Enquiry now

POWER TRANSMISSION AND DISTRIBUTION PROTECTION TRAINING SYSTEM manufacturer in india

MODAL NO: MT-E740

QTY


SCOPE OF LEARNING: 

Study of No load test and Ferranti effects on transmission line.

Load test and calculation of efficiency, regulation and power flow in pi model of TL.

Load test and calculation of efficiency, regulation and power flow in short model of TL

Study of symmetrical and asymmetrical faults on transmission line.

Study of distance protection using distance relay.

SCOPE OF LEARNING: 

Study of No load test and Ferranti effects on transmission line.

Load test and calculation of efficiency, regulation and power flow in pi model of TL.

Load test and calculation of efficiency, regulation and power flow in short model of TL

Study of symmetrical and asymmetrical faults on transmission line.

Study of distance protection using distance relay.

Studies of Auto reclose function of distance relay.

Study of Distribution transformer protection for differential & over current faults.

Power Supplies:

AC Power Supply 0-415V, 4A

Operated on Mains power 415V, 50Hz +10%

SINGLE PHASE POWER SUPPLY MODULE

MCB

Red Indicator

Digital Timer

Reset Switch 

THREE PHASE POWER SUPPLY MODULE (415V,50Hz)

MCB

Emergency Stop

R-Y-B Indicator

 MULTIFUCTION METER MODULE 2NOS.

Digital Multi Function Meter. Measures V, I, PF (0.2 lag – unity 0.2 lead), Hz.

FORWARD/ REVERSE SWITCH MODULE 

? FWD/REV, 3 pole 3 way switch with center OFF, 6A/440V.

CAPACITOR SELECTION MODULE 

? Consisting of VAR compensating capacitors of 2, 4, 6, 8, 10 & 15µF each of 3nos with 3 pole 7 way switch for selection.

DIGITAL METER MODULE (FOR AC)

Digital Voltmeter AC

Digital Ammeter AC 

CURRENT TRANSFORMER MODULE

Current Transformer (3Units) 

SOURCE LINE IN MODULE 

Circuit Connection In

TRIPPING INDICATION MODULE

Lamp Holder 230V (2Units)

POTENTIAL TRANSFORMER MODULE

Potential Transformer (3Units)

TRANSMISSION LINE OUT MODULE 

Connection Out For Transmission Line 

DIFFERENTIAL RELAY (TRANSFORMER PROTECTION) MODULE  1 NO.

Protections: Differential, over current, Under/Over voltage, Under/Over frequency, Reverse power, Earth fault.

9 pin D (M) connector to interface with RTU/SCADA for automation.

Modbus RTU RS 485 for RTU/SCADA interface.

DISTANCE PROTECTION RELAY MODULE

Protections: Distance, Over current, Under/Over voltage, Earth fault.

Auto reclose function of relay

9 pin D (M) connector to interface with RTU/SCADA for automation.

Modbus RTU RS 485 for RTU/SCADA interface.

3PHASE CURRENT SOURCE MODULE

CIRCUIT FOR DISTANCE RELAY

9PIN  JOHNSON CONNECTOR

9PIN  JOHNSON CONNECTOR 

1. TRANSMISSION LINE PANEL TABLE TOP PANEL CONSISTING OF:

? Simulate model for transmission line constructed using R(10ohm/600W), L(0.15H/5A) and C (2.2uF/630V) 6 No. each component.

? Can Simulate model for medium/long (125 km/250 km) length transmission line for ? model.

? Can Simulate model for medium/long (125 km/250 km) length transmission line for T model.

? Fan cooled table top setup for long life.

2. RLC LOAD CONSISTING OF:

? 3nos of 1KW resistors with switch selectable 1(off) + 6 nos. of taps at 100, 112, 150, 175, 200 & 225 ohm & SIL tap of 262 ohm.

? 3 nos. of inductor 1.5H/1A with switch selectable 1(off) + 6 nos. of taps at 0.3, 0.6, 0.75, 0.9, 1.2 & 1.5H.

? Capacitors 440VAC rating (3nos, one per phase) with switch selectable 7nos of value of 2, 5, 10, 15, 20, 30 & 50µF.

? Fan cooled table top setup.

3. 3 PHASE DIMMER PANEL TABLE TOP PANEL CONSISTING OF:

? 3 Phase dimmer I/P : 415VAC, 50Hz, O/P : 0 - 470 V AC, 6A, 3 phase.

4. DISTRIBUTION TRANSFORMER 1 NO.

3 Phase power transformer with connection group YY11,

Input 415VAC, Output 415VAC, 3KVA,

Secondary winding with tapping at +2.5% and +5%.

TRANSMISSION LINE PANEL: 

Table Top Panel consisting of :

Simulated model for short transmission line using R(10 ohm/600W), L(0.15H/5A) & C (2.2uF/630V) 6 No. each component.

Simulated model for medium length 125kms & long lenth 250kms transmission line.

Forced Air cooled using 2 fans.

SALIENT FEATURES:

Front panel built with high class insulated Printed Circuit Breaker well printed circuits and symbols.

Instruction manual.

Patch Cords 4mm (Heavy Duty) 1Meter Length. 

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Modular Based Rack Type Aluminum Extruded Metal cabinet. 

Short Circuit protection with the MCB.

Size of the trainer set 54”x24” 

OPTIONAL ACCESSORIES:

No

POWER TRANSMISSION AND DISTRIBUTION PROTECTION TRAINING SYSTEM  manufacturer in india