Enquiry now

FIRE ALARM TRAINER HEAT AND SMOKE manufacturer in india

MODAL NO: MT-E940

QTY


SCOPE OF LEARNING: 

To work with smoke detector/sensor. 

To work with heat detector/ sensor.

To work with Gas (LPG) leak detector/sensor.

To work with Manual Call Point (MCP).

To work with siren with flasher.

To work with Microcontroller based panel[2 Zone]

SCOPE OF LEARNING: 

To work with smoke detector/sensor. 

To work with heat detector/ sensor.

To work with Gas (LPG) leak detector/sensor.

To work with Manual Call Point (MCP).

To work with siren with flasher.

To work with Microcontroller based panel[2 Zone]

SALIENT FEATURES:

Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.

Instruction manual.

Patch Cords 4mm (Heavy Duty) 1Meter Length.

High Voltage Test Points are Provided With 4mm Safety Sockets

The trainer is housed in Rack Type Channel Extruded Panel

Panel is modular based easy to place and remove the Module. 

Short Circuit protection with the MCB.

Size of the trainer set 36”x24” 

OPTIONAL ACCESSORIES:

No

TECHNICAL SPECIFICATIONS: 

Power Supplies:

Operated on Mains power 230V, 50Hz +10%

1 Phase AC Input Supply Panel 

? 1 Ph. dual MCBs of 2A for short circuit protection

Smoke detector panel 

? Photoelectric smoke sensor

? Operating voltage – 12VDC

? Standby current – 20uA

? Alarm current – 35mA@12VDC

? Alarm output – Remote LED

? Temperature range – 0% ~ 95%RH

Heat detector panel

? Operating voltage : 12VDC

? Static current : <55uA

? Alarm current : <25mA@12VDC

? Alarm output : Remote LED ON,

? Temperature trip point :135°F (57°C)

? Operating temperature : -10°C ~ +50°C, < 95% RH

? Detecting range:50 square meter with the installation height of 6m: 12m

Manual Call Point (MCP) panel 

? Operating voltage : 12VDC

? Resettable type : MCP

? Active/ de active LED indication

? Push to activate & deactivate by plastic key

Siren with flasher panel 

? Operating voltage : 12VDC@500mA

? Power : 6W

? Sound level : 105dB

? Flashing rate : 150 per minute

Gas (LPG) Leak detector panel 

? Operating voltage : 12VDC

? Relay output contacts with max : 24V@1A

? Inbuilt alarm indication buzzer

? Inbuilt heat detector (trip point 60°C)

Control panel

? 2-Zones conventional control panel

? Supply voltage : 230VAC +/-10%/ 50Hz/max 2W

? 12VDC (6V,4.5Ax2nos) rechargeable battery backup

? Zone indication : Fire detection, sensor open, sensor short, sensor bypass & zone test indication

? Status indication - system ON, fire indication, reset key hit, silence key hit, zone fault & siren ON

? Fault indication : AC fail, Hooter fail, Battery low

? 5 keys keypad

? Keypad enable/disable by key lock

? Relay output for siren with max : 24VDC@5A

? Operating temperature : 0 to 50°C, <95%RH

? Auxiliary output : 12VDC/500mA