SCOPE OF LEARNING:
• To work with smoke detector/sensor.
• To work with heat detector/ sensor.
• To work with Gas (LPG) leak detector/sensor.
• To work with Manual Call Point (MCP).
• To work with siren with flasher.
• To work with Microcontroller based panel[2 Zone]
SCOPE OF LEARNING:
• To work with smoke detector/sensor.
• To work with heat detector/ sensor.
• To work with Gas (LPG) leak detector/sensor.
• To work with Manual Call Point (MCP).
• To work with siren with flasher.
• To work with Microcontroller based panel[2 Zone]
SALIENT FEATURES:
• Front panel built with high class insulated Bakelite sheet with Sticker well printed circuits and symbols.
• Instruction manual.
• Patch Cords 4mm (Heavy Duty) 1Meter Length.
• High Voltage Test Points are Provided With 4mm Safety Sockets
• The trainer is housed in Rack Type Channel Extruded Panel
• Panel is modular based easy to place and remove the Module.
• Short Circuit protection with the MCB.
• Size of the trainer set 36”x24”
OPTIONAL ACCESSORIES:
• No
TECHNICAL SPECIFICATIONS:
Power Supplies:
• Operated on Mains power 230V, 50Hz +10%
1 Phase AC Input Supply Panel
? 1 Ph. dual MCBs of 2A for short circuit protection
Smoke detector panel
? Photoelectric smoke sensor
? Operating voltage – 12VDC
? Standby current – 20uA
? Alarm current – 35mA@12VDC
? Alarm output – Remote LED
? Temperature range – 0% ~ 95%RH
Heat detector panel
? Operating voltage : 12VDC
? Static current : <55uA
? Alarm current : <25mA@12VDC
? Alarm output : Remote LED ON,
? Temperature trip point :135°F (57°C)
? Operating temperature : -10°C ~ +50°C, < 95% RH
? Detecting range:50 square meter with the installation height of 6m: 12m
Manual Call Point (MCP) panel
? Operating voltage : 12VDC
? Resettable type : MCP
? Active/ de active LED indication
? Push to activate & deactivate by plastic key
Siren with flasher panel
? Operating voltage : 12VDC@500mA
? Power : 6W
? Sound level : 105dB
? Flashing rate : 150 per minute
Gas (LPG) Leak detector panel
? Operating voltage : 12VDC
? Relay output contacts with max : 24V@1A
? Inbuilt alarm indication buzzer
? Inbuilt heat detector (trip point 60°C)
Control panel
? 2-Zones conventional control panel
? Supply voltage : 230VAC +/-10%/ 50Hz/max 2W
? 12VDC (6V,4.5Ax2nos) rechargeable battery backup
? Zone indication : Fire detection, sensor open, sensor short, sensor bypass & zone test indication
? Status indication - system ON, fire indication, reset key hit, silence key hit, zone fault & siren ON
? Fault indication : AC fail, Hooter fail, Battery low
? 5 keys keypad
? Keypad enable/disable by key lock
? Relay output for siren with max : 24VDC@5A
? Operating temperature : 0 to 50°C, <95%RH
? Auxiliary output : 12VDC/500mA