Vertical Double Wall Digital Autoclave (MT-407 Series)
Product Specification Sheet
Vertical Double Wall Digital Autoclave (MT-407 Series)
The Vertical Double Wall Digital Autoclave (MT-407 Series) is a premium steam sterilization system designed for laboratories, hospitals, pharmaceutical industries, research institutes, and biotechnology facilities. Manufactured by Micro Technologies, it features a double-wall stainless steel construction, digital temperature controller, timer with automatic cut-off, 2 kW heating system, and advanced safety mechanisms for precise and dependable sterilization.
Product Specification
The Vertical Double Wall Digital Autoclave (MT-407 Series) is an advanced laboratory steam sterilizer engineered for accurate, safe, and efficient sterilization of laboratory glassware, surgical instruments, microbiological media, pharmaceutical equipment, culture vessels, and other heat-resistant materials. Manufactured by Micro Technologies, it is ideal for microbiology laboratories, hospitals, research centers, biotechnology companies, pharmaceutical industries, educational institutions, and industrial quality control laboratories.
The autoclave features a double-wall construction with a stainless steel inner chamber and stainless steel outer body, providing excellent corrosion resistance, superior heat retention, and long operational life. The aluminum lid and ring create a secure pressure seal for consistent sterilization performance.
A built-in digital temperature indicator and digital temperature controller allow precise monitoring and regulation of the sterilization cycle. The integrated timer with automatic cut-off buzzer automatically signals the completion of the sterilization process, improving operator convenience and process accuracy.
The unit is equipped with heavy-duty brass operating knobs, a brass water outlet valve, and two insulated lifting handles for easy handling and maintenance. An inner perforated chamber ensures efficient steam circulation, resulting in uniform heat distribution throughout the sterilization chamber.
For maximum operational safety, the MT-407 incorporates a spring-loaded adjustable safety valve, dead-weight safety valve, steam release valve, precision pressure gauge, heat-resistant rubber gasket, and secure six-nut locking arrangement. These safety components ensure reliable pressure control during every sterilization cycle.
Operating at a working pressure of 5–20 PSI, the autoclave is powered by an efficient 2 kW electric heating system, enabling rapid steam generation and dependable sterilization.
The MT-407 Series is available in two chamber capacities to suit different laboratory requirements, making it suitable for both routine laboratory work and higher-volume sterilization applications.
Manufactured by Micro Technologies, every Vertical Double Wall Digital Autoclave undergoes comprehensive testing for temperature accuracy, pressure safety, heating efficiency, and mechanical reliability before delivery.
Features
- Vertical double-wall digital steam autoclave
- Stainless steel inner chamber
- Stainless steel outer body
- Aluminum lid and ring
- Digital temperature indicator
- Digital temperature controller
- Timer with automatic cut-off buzzer
- Heavy-duty brass operating knobs
- Brass water outlet valve
- Spring-loaded adjustable safety valve
- Dead-weight safety valve
- Steam release valve
- Precision pressure gauge
- Inner perforated chamber
- Mild steel tripod stand
- Two insulated lifting handles
- 2 kW electric heating system
- Working pressure: 5–20 PSI
- Durable laboratory-grade construction
Benefits
- Precise digital temperature control
- Automatic sterilization cycle monitoring
- Uniform steam distribution
- Reliable pressure regulation
- Improved operator safety
- Fast and efficient sterilization
- Corrosion-resistant stainless steel construction
- Easy operation and maintenance
- Suitable for continuous laboratory use
- Long service life
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Vertical Double Wall Digital Autoclave |
| Model Series | MT-407 |
| Type | Vertical Steam Sterilizer |
| Construction | Double Wall |
| Inner Chamber | Stainless Steel |
| Outer Body | Stainless Steel |
| Lid Material | Aluminum |
| Ring Material | Aluminum |
| Temperature Control | Digital Temperature Controller |
| Temperature Display | Digital Indicator |
| Timer | Digital Timer with Automatic Cut-Off Buzzer |
| Operating Knobs | Heavy-Duty Brass |
| Water Outlet | Brass Water Outlet Valve |
| Safety Valve | Spring-Loaded Adjustable |
| Additional Safety | Dead-Weight Safety Valve |
| Steam Release Valve | Provided |
| Pressure Gauge | Analog Pressure Gauge |
| Working Pressure | 5–20 PSI |
| Heating System | Electric |
| Heating Load | 2 kW |
| Stand | Mild Steel Tripod Stand |
| Applications | Laboratories, Hospitals, Pharmaceutical Industries, Biotechnology Labs, Research Institutes |
Available Models
| Model | Chamber Size | Capacity |
|---|---|---|
| MT-407(A) | 12" × 12" | 22 Liters |
| MT-407(B) | 12" × 22" | 40 Liters |
Optional Accessories
- PID digital temperature controller
- Digital pressure indicator
- Data logging system
- Stainless steel perforated basket
- Additional sterilization trays
- Spare silicone gasket
- Replacement heating element
- Calibration certificate
- Spare safety valve
SKU System
- MT-407-A
- MT-407-B
FAQs
What is the MT-407 Digital Autoclave used for?
The MT-407 Series is designed for sterilizing laboratory glassware, microbiological media, surgical instruments, pharmaceutical equipment, culture vessels, and other heat-resistant materials.
What is the advantage of the digital controller?
The digital controller provides accurate temperature regulation, while the built-in timer with automatic cut-off improves process control and reduces operator intervention.
What chamber sizes are available?
The MT-407 Series is available in:
- MT-407(A): 12" × 12" (22 Liters)
- MT-407(B): 12" × 22" (40 Liters)
What is the operating pressure?
The autoclave operates at a working pressure of 5–20 PSI, suitable for routine laboratory and medical sterilization.
What safety features are included?
The autoclave includes a spring-loaded safety valve, dead-weight safety valve, steam release valve, pressure gauge, rubber gasket, secure locking system, and automatic timer cut-off.
What is the heating capacity?
The unit is fitted with a 2 kW electric heating system for rapid steam generation and efficient sterilization.
Where is the MT-407 Series commonly used?
It is widely used in hospitals, microbiology laboratories, pharmaceutical industries, biotechnology facilities, universities, research institutes, diagnostic laboratories, and industrial quality control laboratories.
Can the MT-407 Series be supplied in bulk?
Yes. Micro Technologies supplies the MT-407 Series for institutional procurement, OEM manufacturing, government tenders, distributors, export projects, and bulk laboratory equipment requirements.
Why Choose Our Products
- Advanced digital temperature control
- Automatic timer with cut-off buzzer
- Double-wall stainless steel construction
- Reliable steam sterilization
- Efficient 2 kW heating system
- Comprehensive safety mechanisms
- Heavy-duty brass fittings
- OEM manufacturing support
- Competitive B2B pricing
- Bulk institutional supply
- Strict quality inspection
- Reliable after-sales service
Call to Action
Choose the Vertical Double Wall Digital Autoclave (MT-407 Series) from Micro Technologies for accurate, safe, and efficient steam sterilization in laboratories, hospitals, pharmaceutical industries, research institutes, and educational institutions. Contact us today for pricing, customized specifications, OEM manufacturing, government tenders, distributor inquiries, or a competitive quotation.