Open Wound Solenoid - Product Image

Open Wound Solenoid

Model Number: MTE-021

The Open Wound Solenoid is a practical physics laboratory apparatus used for studying magnetic fields produced by a current-carrying coil. It features a widely spaced heavy gauge copper wire coil capable of carrying current up to 10 A. The coil is mounted on a base with 4 mm socket terminals for convenient electrical connections. A support is positioned across the centre of the coil to allow students to demonstrate and observe the magnetic field using iron filings or a small compass. With a coil dimension of approximately 150 × 50 mm, the unit is suitable for electromagnetism demonstrations, physics experiments and laboratory teaching. Micro Technologies supplies practical equipment for educational and scientific laboratory applications.

View Cart

Product Specification

The Open Wound Solenoid is designed for practical investigation of magnetic fields generated by an electric current flowing through a coil. Its open construction provides clear access to the coil and allows students to observe magnetic field patterns during laboratory demonstrations.

The apparatus consists of a widely spaced heavy gauge copper wire coil capable of carrying current up to 10 A. The coil is mounted on a sturdy base and fitted with 4 mm socket terminals, providing convenient connections to an appropriate electrical supply or experimental circuit.

A support is positioned across the centre of the coil, providing a suitable area for demonstrating the magnetic field. Students can use iron filings to visualize the field pattern or a small compass to investigate the direction of the magnetic field produced by the energized coil.

The open-wound construction makes the apparatus particularly useful for teaching electromagnetism because the magnetic field around the coil can be directly investigated. It can support experiments involving current, magnetic field formation and the behaviour of magnetic fields around current-carrying conductors.

The coil has an approximate dimension of 150 × 50 mm, providing a compact setup for laboratory demonstrations. Its heavy gauge copper construction is suitable for practical experiments requiring higher current capacity.

The Open Wound Solenoid is suitable for physics laboratories, electrical engineering departments, colleges, universities and technical training institutes. It can be used for classroom demonstrations as well as hands-on student experiments.

Micro Technologies supplies educational and laboratory equipment for practical physics and electrical training. This apparatus provides a straightforward solution for demonstrating magnetic field principles and current-carrying coil behaviour.

Features

  • Widely spaced heavy gauge copper wire coil
  • Current carrying capacity up to 10 A
  • Mounted on a practical base
  • 4 mm socket terminals
  • Centre support across the coil
  • Suitable for iron filing demonstrations
  • Suitable for compass-based magnetic field studies
  • Approximate coil dimension of 150 × 50 mm
  • Open construction for easy field observation
  • Suitable for physics and electromagnetism experiments

Benefits

  • Makes magnetic field patterns easier to observe
  • Supports hands-on electromagnetism learning
  • Allows demonstrations using iron filings or a compass
  • Suitable for higher-current laboratory experiments
  • Provides convenient electrical connections
  • Useful for classroom and laboratory demonstrations

Product Specifications

Specification Details
Product Name Open Wound Solenoid
Product Type Magnetic Field Demonstration Apparatus
Coil Material Heavy Gauge Copper Wire
Coil Type Widely Spaced Open Wound
Maximum Current 10 A
Connection 4 mm Socket
Centre Support Included
Coil Dimension Approx. 150 × 50 mm
Field Demonstration Iron Filings or Small Compass
Application Magnetic Field & Electromagnetism Experiments
Usage Physics Laboratory & Educational Training

Available Variants

Standard Open Wound Solenoid

Suitable for magnetic field demonstrations using iron filings or a small compass.

Applications

  • Magnetic field demonstrations
  • Electromagnetism experiments
  • Current-carrying coil experiments
  • Physics practical laboratories
  • Electrical engineering laboratories
  • Magnetic field visualization
  • Compass-based magnetic field studies
  • Science education and training

FAQs

What is the Open Wound Solenoid used for?

It is used to demonstrate and study the magnetic field produced by a current-carrying coil. Students can observe the field using iron filings or a small compass.

What is the maximum current capacity?

The heavy gauge copper coil is capable of carrying current up to 10 A.

What type of terminals are provided?

The apparatus is fitted with 4 mm socket terminals for electrical connections.

How can the magnetic field be observed?

The magnetic field can be demonstrated using iron filings or investigated using a small compass positioned around the coil.

What are the approximate coil dimensions?

The coil has an approximate dimension of 150 × 50 mm.

Where can this apparatus be used?

It is suitable for physics and electrical laboratories, colleges, universities, technical institutes and electromagnetism training environments.

Why Choose Our Products

  • Heavy gauge copper coil construction
  • Current capacity up to 10 A
  • Clear magnetic field demonstration arrangement
  • Convenient 4 mm socket connections
  • Suitable for practical physics laboratory training

Call to Action

Contact Micro Technologies for pricing, bulk orders and institutional requirements for the Open Wound Solenoid. Request a quotation for physics, electromagnetism and electrical laboratory applications.

+91-9416155221 +91-9896055098