Primary and Secondary Coil - Product Image

Primary and Secondary Coil

Model Number: MTE-017

Primary and Secondary Coil is a practical physics laboratory apparatus for demonstrating electromagnetic induction and introducing the working principle of a transformer. The assembly consists of separate primary and secondary coils mounted on plastic spools, with two binding posts provided on each coil for electrical connections. The primary winding contains approximately 480 turns, while the secondary winding contains approximately 3800 turns, allowing students to study the relationship between coil turns and induced voltage. A soft iron core can be inserted through the secondary coil for induction experiments. The apparatus is suitable for physics laboratories, colleges, universities and educational institutes. Micro Technologies supplies this electromagnetic induction apparatus for practical demonstrations, laboratory teaching and institutional procurement.

View Cart

Product Specification

The Primary and Secondary Coil is a straightforward laboratory apparatus for demonstrating the principle of electromagnetic induction and helping students understand the basic operation of a transformer. It provides separate windings with different numbers of turns, allowing practical investigation of how changes in magnetic flux can induce voltage in a nearby coil.

The apparatus consists of a primary coil and a secondary coil mounted separately on durable plastic spools. Each coil is provided with two binding posts, giving users convenient connection points for compatible laboratory circuits, measuring instruments or power sources. The clear separation between the windings also makes the relationship between primary and secondary circuits easier to understand during classroom demonstrations.

The primary winding incorporates approximately 480 turns, while the secondary winding contains approximately 3800 turns. This difference in winding ratio provides a useful setup for demonstrating the effect of coil turns on induced voltage. Students can observe and discuss transformer action, magnetic coupling and electromagnetic induction using suitable laboratory instruments.

A soft iron core can be passed through the secondary coil for induction experiments. The removable core allows instructors to demonstrate how the presence of a ferromagnetic material affects the magnetic path between the coils. This makes the apparatus useful for experiments involving magnetic flux concentration, mutual induction and transformer principles.

The unit can be used alongside a suitable galvanometer, power supply, measuring instrument or other compatible physics laboratory equipment. Galvanometer, bar magnets and external accessories are not included unless specifically mentioned in the quotation.

Its simple construction makes the apparatus particularly useful for practical teaching because students can clearly identify the primary winding, secondary winding, connection terminals and magnetic core. It can support laboratory exercises in electromagnetism, electrical science and introductory transformer theory.

Micro Technologies supplies this Primary and Secondary Coil for educational laboratories, institutional setups and physics experiment requirements. The reusable construction and uncomplicated connection arrangement make it suitable for repeated practical sessions when handled and stored correctly.

Features

  • Separate primary and secondary coil arrangement.
  • Primary winding with approximately 480 turns.
  • Secondary winding with approximately 3800 turns.
  • Coils mounted on durable plastic spools.
  • Two binding posts provided on each coil.
  • Removable soft iron core for induction experiments.
  • Suitable for transformer principle demonstrations.
  • Useful for electromagnetic induction experiments.
  • Clear arrangement for practical physics teaching.
  • Compatible with suitable external laboratory measuring instruments.

Benefits

  • Supports practical learning: Helps students understand electromagnetic induction through direct experimentation.
  • Demonstrates transformer action: Different primary and secondary turns provide a useful basis for studying winding ratios.
  • Flexible experimental setup: Separate terminals allow convenient connection to compatible laboratory equipment.
  • Magnetic-core experimentation: The removable soft iron core enables comparison of magnetic coupling conditions.
  • Reusable laboratory component: Suitable for repeated demonstrations with appropriate handling.
  • Low-maintenance construction: Plastic spool mounting provides a simple and practical laboratory arrangement.
  • Strong procurement value: Useful for physics departments, colleges, universities and educational laboratory setups.

Product Specifications

Specification Details
Product Name Primary and Secondary Coil
Internal Model No. MT-PSC-480
Product Type Electromagnetic Induction / Transformer Coil Apparatus
Primary Coil Approx. 480 Turns
Secondary Coil Approx. 3800 Turns
Coil Mounting Plastic Spools
Binding Posts 2 Per Coil
Core Soft Iron, Removable
Core Function Magnetic Flux / Induction Experiments
Calibration Not Applicable
Color Black / Natural Plastic Components
Usage/Application Electromagnetic Induction and Transformer Experiments
Suitable For Physics Laboratories, Colleges, Universities and Educational Institutes
Accessories Not Included Galvanometer, Bar Magnets and External Measuring Equipment
Compliance Manufactured according to applicable laboratory equipment quality practices

Available Variants

  • Primary Coil – approximately 480 turns
  • Secondary Coil – approximately 3800 turns
  • Primary and Secondary Coil Set with removable soft iron core
  • Custom winding configurations may be considered for specific laboratory requirements

SKU System

  • MT-PSC-480 – Primary & Secondary Coil Set
  • MT-PSC-480-BULK – Bulk Institutional Supply
  • MT-PSC-480-CUS – Custom Winding Requirement

FAQs

What is the Primary and Secondary Coil used for?

The apparatus is used to demonstrate electromagnetic induction and transformer principles.
It allows students to study how a changing magnetic field can induce voltage in a secondary winding.
It is commonly used in practical physics and electrical science laboratories.

How many turns are present in the coils?

The primary coil has approximately 480 turns, while the secondary coil has approximately 3800 turns.
The difference in turns provides a useful setup for demonstrating transformer action.
Actual winding specifications should be confirmed with the product quotation where required.

What is the purpose of the soft iron core?

The soft iron core provides a magnetic path between the coils and helps concentrate magnetic flux.
It can be inserted into the coil assembly during electromagnetic induction experiments.
Its removable construction also allows different experimental arrangements.

Does the apparatus require calibration?

The coils are passive laboratory components and do not normally require instrument-style calibration.
However, the number of turns, dimensions and electrical continuity can be checked during quality inspection.
External measuring instruments used with the apparatus should have appropriate calibration.

Is this apparatus suitable for transformer experiments?

Yes, it is suitable for basic transformer and mutual-induction demonstrations.
The different numbers of turns in the primary and secondary windings help illustrate the relationship between turns ratio and induced voltage.
A suitable power source and measuring equipment are required for experimental use.

Can colleges and universities order these coils in bulk?

Yes, bulk supply can be arranged for educational institutions and laboratory procurement projects.
Multiple sets can be supplied according to the required laboratory quantity.
Institutional buyers can request a quotation based on their quantity and technical requirements.

Can the coil winding be customized?

Customized winding specifications may be possible depending on the required application.
Turn count, coil configuration and other technical parameters can be evaluated before production.
Buyers should provide detailed requirements when requesting customization.

How durable are the coils?

The coils are mounted on plastic spools for convenient laboratory handling and repeated educational use.
They should be protected from excessive impact, moisture and improper electrical connections.
Correct storage and careful handling can extend their service life.

How should the Primary and Secondary Coil be maintained?

Keep the coil assembly clean and dry and inspect the binding posts periodically.
Check connections before each experiment and avoid applying unsuitable electrical input.
The apparatus should be stored safely after laboratory use.

Are the galvanometer and bar magnets included?

The standard apparatus does not include external equipment such as a galvanometer or bar magnets.
These items can be used separately where required for specific experiments.
The supplied configuration should be confirmed against the final quotation or product package.

How is the apparatus packaged for shipping?

The coils and soft iron core should be protected against impact and movement during transportation.
Suitable protective packaging can be used for individual sets as well as bulk institutional shipments.
Packaging requirements can be discussed according to order quantity.

What is the shipping timeline for bulk orders?

Dispatch time depends on stock availability, order quantity and customization requirements.
Standard configurations can generally be processed according to current inventory.
The confirmed lead time can be provided with the commercial quotation.

Why Choose Our Products

  • Controlled manufacturing standards for consistent coil construction and practical laboratory use.
  • Strict quality inspection of winding arrangement, terminals and mechanical assembly.
  • Precision-oriented engineering supporting reliable electromagnetic induction demonstrations.
  • Durable laboratory construction suitable for repeated academic experiments.
  • Bulk supply capability for colleges, universities, distributors and institutional laboratory projects.

Call to Action

Equip your physics laboratory with a practical apparatus for electromagnetic induction and transformer experiments. Micro Technologies supports bulk inquiries, institutional orders, distributor requirements and customized coil specifications. Share your required quantity and technical requirements to receive a suitable quotation.

+91-9416155221 +91-9896055098