Enquiry now

Nozzle Meter Test Rig manufacturer in india

MODAL NO: MTFM-112

QTY


The present set-up is designed to study a nozzle meter and to calculate fluid discharge through it. By determining the co-efficient of discharge of this nozzle meter it can be used as a flow meter and can be installed in a fluid line. The apparatus consists of a pipe line in which a transparent nozzle meter is installed. The pressure tapings from the nozzle meter is taken to pressurized differential pressure manometer to measure pressure difference.

The present set-up is designed to study a nozzle meter and to calculate fluid discharge through it. By determining the co-efficient of discharge of this nozzle meter it can be used as a flow meter and can be installed in a fluid line. The apparatus consists of a pipe line in which a transparent nozzle meter is installed. The pressure tapings from the nozzle meter is taken to pressurized differential pressure manometer to measure pressure difference. Present set-up is self-contained water re-circulating unit, provided with a sump tank, centrifugal pump etc. Water is pumped by means of centrifugal pump and passing through the test section, it returns back to the sump which make the system re-circulating type. Flow of water is diverted either to measuring tank or sump tank with the means of a flow diverter, when needed. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank with piezometer and stopwatch. The supplied set-up is complete in all respect. Only water supply and electricity supply is to be provided by the end user for running the set-up.

•Tanks will be made of Stainless Steel.

•An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus.

•The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.

Experimentation/Learning Objectives

••To measure discharge through Nozzle meter.

••To calculate co-efficient of discharge for Nozzle meter

Utilities Required

•Electricity supply: Single Phase, 220 V AC, 50 Hz, 5-15 Amp. combined socket with earth connection. Earth voltage should be less than 5 volts.

•Water Supply (Initial Fill).

•Floor Drain required.

•Floor Area Required: 2 m 0x.75 m

Nozzle meterTest section made of Clear Acrylic. Compatible to 1” dia pipe.
Water Circulation½ HP Pump, Crompton/Standard make. .
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs.
Sump TankCapacity 50 Ltrs.
Stop Watch Electronic
Pressure measurementBy Pressurized differential pressure manometer
Control Panel Comprises ofStandard make On/Off Switch, Mains Indicator, etc.