The present set-up is designed to study the Plate type heat exchanger. It consists of a frame in which independent metal plates are clamped between a head and follower. The plates are sealed at their outer edges and around the ports by gaskets, which are so arranged that the fluids can be directed alternately into passages formed between the plates. The hot fluid enters at the top on the right side of the fixed end cover, flows downwards through alternate channels between the plates and leaves at the bottom. The cold fluid enters at the bottom of the left side of the fixed end cover, flows in counter current flow through alternate channels between the plates and leaves at the top. For hot water, a recirculating type water bath having PID temperature controller and a magnetic pump is provided. Cold water at constant head condition is to be provided from laboratory overhead tank. Flow rates are measured by using Rotameters. The temperature of hot and cold fluids at inlet and outlet of heat exchanger can be measured by Digital Temperature Indicator.

The present set-up is designed to study the Plate type heat exchanger. It consists of a frame in which independent metal plates are clamped between a head and follower. The plates are sealed at their outer edges and around the ports by gaskets, which are so arranged that the fluids can be directed alternately into passages formed between the plates. The hot fluid enters at the top on the right side of the fixed end cover, flows downwards through alternate channels between the plates and leaves at the bottom. The cold fluid enters at the bottom of the left side of the fixed end cover, flows in counter current flow through alternate channels between the plates and leaves at the top. For hot water, a recirculating type water bath having PID temperature controller and a magnetic pump is provided. Cold water at constant head condition is to be provided from laboratory overhead tank. Flow rates are measured by using Rotameters. The temperature of hot and cold fluids at inlet and outlet of heat exchanger can be measured by Digital Temperature Indicator.

  • An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus.
  • The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.

Experimentation/Learning Objectives

To calculate : -

•LMTD

•Heat transfer rate

•Overall Heat Transfer Co-efficient.

Utilities Required

•Water supply: 5 LPM at 1 Bar and Floor drain.

•Electricity Supply: 1 Phase, 220 V AC, 50 Hz, 32 amp MCB with earth connection (Earth voltage should be less than 5 volts)

•Floor area: 1.0 m x 0.5 m.

SystemWater to Water
Plates Material Stainless Steel, 6 Nos. Length 425 mm, Width 125 mm (approx.)
Water Flow Measurement Rotameters (2Nos.) one each for cold & hot fluid.
Hot Water TankMade of Stainless steel (Insulated with ceramic wool)
Hot Water CirculationMagnetic Pump
Heaters Nichrome wire heater (2Nos)
Control panel comprising of :

Digital Temp. Controller PID Controller, 0-199.9°C (For Hot Water Tank)

Digital Temp. Indicator : 0-199.9°C, with multi-channel switch

Temperature Sensors RTD PT-100 type-5Nos.

Non Contact type.With Standard make On/Off switch, Mains Indicator etc.